NEMA 1 – Enclosures constructed
for indoor use to provide a degree of protection
to personnel against incidental contact with the
enclosed equipment and to provide a degree of
protection against falling dirt.
NEMA 2 – Same as NEMA
1 including protection against dripping and light
splashing of liquids.
NEMA 3 – Enclosures constructed
for either indoor or outdoor use to provide a
degree of protection to personnel against incidental
contact with the enclosed equipment; to provide
a degree of protection against falling dirt, rain,
sleet, snow, and windblown dust; and that will
be undamaged by the external formation of ice
on the enclosure.
NEMA 3R – Same as NEMA
3 excluding protection against windblown dust.
NEMA 3S – Enclosures constructed
for either indoor or outdoor use to provide a
degree of protection to personnel against incidental
contact with the enclosed equipment; to provide
a degree of protection against falling dirt, rain,
sleet, snow, and windblown dust; and in which
the external mechanism(s) remain operable when
ice laden.
NEMA 4 – Enclosures constructed
for either indoor or outdoor use to provide a
degree of protection to personnel against incidental
contact with the enclosed equipment; to provide
a degree of protection against falling dirt, rain,
sleet, snow, windblown dust, splashing water,
and hose-directed water; and that will be undamaged
by the external formation of ice on the enclosure.
NEMA 4X – Same as NEMA
4 including protection against corrosion.
NEMA 5 – Enclosures constructed
for indoor use to provide a degree of protection
to personnel against incidental contact with the
enclosed equipment; to provide a degree of protection
against falling dirt and against settling airborne
dust, lint, fibers; to provide a degree of protection
against dripping and light splashing of liquids.
NEMA 6 – Enclosures constructed
for either indoor or outdoor use to provide a
degree of protection to personnel against incidental
contact with the enclosed equipment; to provide
a degree of protection against falling dirt; against
hose-directed water and the entry of water during
occasional temporary submersion at a limited depth;
and that will be undamaged by the external formation
of ice on the enclosure.
NEMA 6P – Same as NEMA
6 including protection against the entry of water
during prolonged submersion at a limited depth.
NEMA 7 – Enclosures are
for indoor use in locations classified as Class
I, Groups A, B, C, or D and shall be capable of
withstanding the pressures resulting from an internal
explosion of specified gases, and contain such
an explosion sufficiently that an explosive gas-air
mixture existing in the atmosphere surrounding
the enclosure will not be ignited. Enclosed heat
generating devices shall not cause external surfaces
to reach temperatures capable of igniting explosive
gas-air mixtures in the surrounding atmosphere.
Enclosures shall meet explosion, hydrostatic,
and temperature design tests.
NEMA 9 – Enclosures are
intended for indoor use in locations classified
as Class II, Groups E, F, or G, and shall be capable
of preventing the entrance of dust. Enclosed heat
generating devices shall not cause external surfaces
to reach temperatures capable of igniting or discoloring
dust on the enclosure or igniting dust-air mixtures
in the surrounding atmosphere. Enclosures shall
meet dust penetration and temperature design tests,
and aging of gaskets (if used).
NEMA 12 – Enclosures constructed
(without knockouts) for indoor use to provide
a degree of protection to personnel against incidental
contact with the enclosed equipment; to provide
a degree of protection against falling dirt; against
circulating dust, lint, fibers; and against dripping
and light splashing of liquids.
NEMA 12K – Same as NEMA
12 including enclosures constructed with knockouts.
NEMA 13 – Enclosures constructed
for indoor use to provide a degree of protection
to personnel against incidental contact with the
enclosed equipment; to provide a degree of protection
against falling dirt; against circulating dust,
lint, fibers; and against the spraying, splashing,